DiveCommand Tech mode gradient factor settings: GF Low and GF High sliders set to 30/70, with presets 20/70, 30/70, 50/70 and 50/85
DepthPlanner · Decompression theory

Gradient factors, explained

Two numbers, like 30/70, decide how conservative a Bühlmann decompression plan is. Here is what each one does, shown with real DiveCommand results for a 50 m trimix dive.

The limit the numbers are measured against

DiveCommand uses the Bühlmann ZHL-16C model. It tracks nitrogen and helium in 16 theoretical tissue compartments, from fast ones with a 5-minute half-time to slow ones at 635 minutes.

Each compartment has an M-value: the highest inert-gas pressure Bühlmann allows it to hold at a given ambient pressure before decompression sickness becomes likely. The M-value rises with depth, which is why you can carry more gas at 21 m than at the surface.

Raw M-values allow no margin. A gradient factor sets how much of the gap between ambient pressure and the M-value you are willing to use:

allowed tissue pressure = Pambient + GF × (M-value − Pambient)

A gradient factor of 100% is the raw M-value. A gradient factor of 0% would allow no supersaturation at all. Every planner and computer that offers gradient factors uses two of them:

  • GF Low applies at your first decompression stop. It decides how deep that stop is.
  • GF High applies when you surface. It decides how long the shallow stops are, and it sets your no-decompression limit.

Between the first stop and the surface, the allowed gradient factor rises in a straight line from GF Low to GF High.

Try it · DiveCommand results 50 m · 20 min at depth · Trimix 18/45 · EAN50 at 21 m · O₂ at 6 m
M-value (100%) Your gradient-factor limit Ambient pressure

Shown for compartment 5 (27-minute half-time, nitrogen). Every compartment has its own M-value line; the planner applies the same gradient factors to all 16.

First stop
24
metres
Total deco
30
minutes
Run time
59
56 from depth

Calculated with DiveCommand’s Bühlmann ZHL-16C engine: salt water at sea level, descent 14 m/min not counted in bottom time, ascent 9 m/min, stops every 3 m, last stop 6 m. Planning illustration only.

GF Low moves the first stop

GF Low only matters once a dive needs decompression. It caps how far your tissues may be supersaturated when you arrive at the first stop. A low GF Low stops you deeper; a high GF Low lets you ascend further first.

SettingFirst stopTotal decoRun time

On this dive, moving GF Low from 20 to 70 lifts the first stop from 27 m to 18 m but changes total deco by only 4 minutes. GF Low shapes where you start decompressing far more than how long you decompress.

The deep-stop question

Very low GF Low values were popular when deep stops were believed to control bubble growth. The evidence has moved the other way. A US Navy Experimental Diving Unit trial of about 400 air dives to 170 fsw for 30 minutes compared a deep-stop schedule with a traditional shallow-stop schedule of the same total decompression time. Decompression sickness was more frequent with the deep stops, because slow tissues kept loading gas during the extra time spent deep.

That is one reason many divers and manufacturers have moved GF Low up from the 20–30 range. DiveCommand’s Technical Mode default is 50/70, and Recreational Mode uses 50/85; these match Shearwater’s current presets.

GF High sets the shallow stops and your NDL

GF High is the margin you keep when you surface. Lowering it adds time at the shallowest stops, where it costs the most: on this dive, going from GF High 90 to 60 adds 13 minutes of deco, 11 of them at the 12, 9 and 6 m stops.

SettingTotal decoTime at 6 mRun timeCNS

For no-decompression diving, GF High is the only number that counts. Your NDL is the time you can stay before a direct ascent would put any compartment over GF High at the surface; GF Low never comes into play. Air, salt water, sea level:

DepthGF High 70GF High 85GF High 95

NDLs in minutes, from DiveCommand’s engine, bottom time counted from leaving the surface. Your computer may differ by a minute or two because of ascent-rate and rounding assumptions.

Setting gradient factors in DiveCommand

Recreational Mode uses 50/85 and does not let you change it. Switch on Tech Mode and open the Gradient Factors card to set GF Low and GF High with the sliders, or pick a preset:

20/70
Very conservative

Deepest first stop and the most time at the shallow stops.

30/70
Conservative

A common technical choice, and the setting in the dive above.

50/70
Factory default

Tech Mode’s default, the same as Shearwater’s Tec preset.

50/85
Moderate

Recreational Mode’s setting, the same as Shearwater’s Rec preset.

To compare DiveCommand with your dive computer, match more than the gradient factors. Set the Deco Profile card to the same bottom-time convention, ascent rate and last stop (3 m or 6 m) your computer uses, and the same water type. Two tools at the same gradient factors can still differ by a minute or two at individual stops because of rounding and ascent conventions.

What gradient factors do not do
  • They do not make a plan safe. They tune one model of decompression stress, and individual risk still varies with exertion, temperature, hydration and fitness.
  • They do not change your gas limits. ppO₂, MOD and CNS oxygen exposure are separate, and a more conservative GF High raises CNS because you spend longer on oxygen.
  • Raising GF High toward 95–100 removes almost all margin. Do not make a profile more aggressive without decompression training.

DiveCommand is a planning tool from Diverobotix LLC and does not replace training or a dive computer. Plan with it at depthplanner.com.

Further reading: Erik Baker, “Clearing Up the Confusion About Deep Stops”; DAN Alert Diver, “Deep Stops”; US Navy Experimental Diving Unit Technical Report 11-06.

Scroll to Top