NAVCOMMAND · TECHNICAL METHODOLOGY

How NavCommand calculates

NavCommand plans commercial air and nitrox dives from the U.S. Navy Diving Manual, Revision 7 tables, and checks them against OSHA 29 CFR 1910 Subpart T. This page sets out each rule, where it comes from, and the few places where NavCommand is deliberately more conservative than the tables.

01

The tables NavCommand uses

USN Rev 7 tableWhat NavCommand uses it for
Table 9-7 · No-decompression limits and repetitive group designatorsNo-decompression limit for each depth and the repetitive group on surfacing
Table 9-8 · Residual nitrogen timeSurface-interval credit and residual nitrogen time (RNT) for repetitive dives
Table 9-9 · Air decompression tableStops, stop times, total ascent time and surfacing group for decompression dives
Table 9-4 · Sea level equivalent depthConverting actual depth at altitude to the table row
Table 9-5 · Groups on initial ascent to altitudeStarting group for a crew that arrived at altitude less than 12 hours ago
Table 9-6 · Surface interval before ascent to altitudeWait before flying or driving higher after diving

NavCommand covers air and nitrox only. It has no helium (mixed-gas) schedules: the trimix option is disabled, and a helium mix is never planned on the air tables. Custom nitrox below 21% oxygen is not accepted, because it would make the air tables non-conservative.

02

Depth and bottom time

  • The table row is the exact or next deeper published row: 30, 35, 40, 45, 50, 55, 60, then every 10 fsw to 190. Anything shallower than 30 fsw is planned on the 30 fsw row (conservative). Depth buttons run from 35 to 190 fsw.
  • Bottom time follows the Navy definition: from leaving the surface to leaving the bottom, rounded up to the whole minute. The schedule is the exact or next longer published bottom time.
  • The air tables end at 190 fsw, including after the altitude correction. Deeper is shown as “beyond the tables” and is not planned.
  • Fresh water never makes a dive shallower in the tables. The table row always comes from the depth as entered. Water type is used only for oxygen calculations.
03

No-decompression limits and repetitive groups

For a no-decompression dive, NavCommand reads Table 9-7 at the table row. The repetitive group is the first group whose time is equal to or longer than the bottom time (or the equivalent single dive time on a repetitive dive).

Cold or strenuous dives

When the Cold / Strenuous switch is on, NavCommand applies three adjustments:

  • NavCommand margin (Rev 7 §9-6.1 does not require it): a decompression dive uses the next longer bottom-time schedule in Table 9-9: one row longer than the dive’s own row.
  • NavCommand margins (not Navy rules): the no-decompression limit is reduced by 20% (rounded down), and the repetitive group is looked up at 1.25× the bottom time (rounded up). Both are extra safety factors.
04

Decompression dives

  • A dive whose bottom time (or equivalent single dive time) exceeds the adjusted no-decompression limit uses Table 9-9, at the exact or next longer bottom-time row for that depth.
  • If that row has no stops (for example, the cold margin pushed a dive just past the limit), NavCommand uses the next row that does have stops. A dive that needs decompression always gets a schedule with stops.
  • Stops and stop times are shown as published. The total ascent time is shown to the nearest minute; the manual prints it in minutes and seconds. The surfacing group is the one printed on that row.
  • Every published Table 9-9 row to 190 fsw is loaded, including the longest rows (for example 150 fsw / 120 and 180 min) that Rev 7 lists for emergencies such as entrapment.
  • Exceptional exposure (Rev 7 9-10): every row at or below the line printed in Table 9-9 where in-water air decompression becomes exceptional exposure (more than 90 minutes of decompression) is flagged, including rows that still show Group Z. The flag says what the manual says: exceptional exposure schedules are for emergencies, and planned exceptional exposure dives need Commanding Officer approval (OPNAVINST 3150.27).
  • No repetitive group (9-9.1 item 9): a row that prints no repetitive group is flagged separately. No dive deeper than 20 fsw is allowed for 18 hours after it. Table 9-6 has no group for these rows, so NavCommand applies the 48-hour exceptional-exposure wait before flying or driving higher.
  • Decompression mode: NavCommand plans the in-water air schedule and also shows the mode note Table 9-9 prints for that row: air/O₂ or surface decompression on oxygen (SurDO₂) strongly recommended once air stop time passes 15 minutes (9-8.4); in-water air/O₂ or SurDO₂ required below the exceptional-exposure line; SurDO₂ required, or SurDO₂ only, on the deepest bands.
  • If the sea level equivalent depth is deeper than 190 fsw, or the bottom time is longer than the last Table 9-9 row for that depth, no schedule is given and the dive is not planned. Rev 7 lists air schedules deeper than 190 fsw, but every air dive deeper than 190 fsw is exceptional exposure, so they are not in the planner.
  • CNS oxygen loading is also worked out for every stop, at that stop’s ppO₂.
05

Repetitive dives and residual nitrogen

Surface interval of 10 minutes or more

  1. The surfacing group is reduced by the surface interval using Table 9-8. The reduction always starts from the group at surfacing, never from an already-reduced group.
  2. Once the interval passes the end of the table, the diver is clean.
  3. Otherwise NavCommand reads the RNT for the new group at the next dive’s table row.
ESDT = bottom time + RNT   ·   adjusted no-deco limit = NDL − RNT

When a repetitive dive is not allowed

  • After a schedule with no repetitive group (including every exceptional exposure row, and dives beyond the tables): a red banner blocks any dive deeper than 20 fsw until 18 hours after surfacing (9-9.1 item 9). At altitude the 20 fsw test uses the sea level equivalent depth.
  • A repetitive dive that would need an exceptional exposure schedule gets a red banner: Rev 7 does not allow it (9-9.1 item 10).

Surface interval under 10 minutes

The Navy treats two dives less than 10 minutes apart as one dive: the deepest depth and the combined bottom time. NavCommand applies that rule and never lets the result come out lower than the residual-nitrogen method:

ESDT = bottom time + max( previous dive’s ESDT , RNT at the deeper row )

Dive 1 starts from the diver’s real status

Dive 1 is not assumed to be a clean dive. When you choose who you are planning for, NavCommand uses the later (more loaded) of two groups as the starting group:

  • the diver’s current group from the dive log (section 06), and
  • the altitude-arrival group from Table 9-5, if the crew arrived less than 12 hours ago (section 07).

The plan, profile chart, printouts, commercial dive plan, gas planning and contingency schedules all use the resulting starting group, RNT and ESDT.

06

The rolling dive log

  • Each diver’s finalized dives are walked in time order, whatever the calendar date, so night shifts that cross midnight carry their nitrogen forward.
  • Between dives NavCommand applies the Table 9-8 surface-interval credit. A dive under 10 minutes after the last one is combined with it, as in section 05.
  • If a dive has no entry time, it is backed off from the surfacing time by the bottom time plus the ascent (30 ft/min, or the logged decompression runtime). An earlier entry time is the conservative assumption.
  • A logged dive that needed decompression by the tables, but was logged without it, is flagged. An exceptional exposure, a schedule with no repetitive group, or a dive beyond the tables blocks any dive deeper than 20 fsw for 18 hours after surfacing (9-9.1 item 9); the diver carries Group Z with no surface-interval credit until then.
07

Diving at altitude

NavCommand follows the USN Rev 7 altitude procedure (Chapter 9).

1 · Which altitude column

  • 300 ft or lower: no correction (sea level).
  • Above 300 ft: the elevation is rounded up to the next 1,000 ft. A 6,225 ft site uses the 7,000 ft column.
  • Above 10,000 ft: outside the Rev 7 procedures. NavCommand refuses to plan until the altitude is corrected.

2 · Dive depth → Table 9-4

The actual depth is looked up in Table 9-4 to get the sea level equivalent depth, which then goes to the next deeper table row. The Table 9-4 values are exactly as printed. Between 300 and 1,000 ft the manual corrects only dives deeper than 145 fsw, and its 1,000 ft column reflects that. Where Table 9-4 leaves a cell blank, the depth converts to deeper than 190 fsw and the dive is not planned.

3 · Decompression stops → actual stop depth

Each Table 9-9 stop is held shallower, in proportion to the lower surface pressure. Stop times do not change. Printouts show the table stop alongside.

actual stop depth = table stop depth × (Paltitude ÷ Psea level), rounded to the nearest foot (halves up)

The ratios are the manual’s own, to three decimals (below). With them the formula gives exactly the Equivalent Stop Depths printed under Table 9-4 for 10–60 fsw stops, and the same formula covers deeper stops (Rev 7 9-13.1.2). Between 300 and 1,000 ft, a dive to 145 fsw or shallower is not corrected at all, so its stops are the table stops; dives deeper than that use the 1,000 ft ratio.

Altitude (ft)1,0002,0003,0004,0005,0006,0007,0008,0009,00010,000
Palt ÷ Psea0.9640.9300.8960.8640.8320.8010.7720.7430.7150.688
20 fsw stop held at19 ft19 ft18 ft17 ft17 ft16 ft15 ft15 ft14 ft14 ft
30 fsw stop held at29 ft28 ft27 ft26 ft25 ft24 ft23 ft22 ft21 ft21 ft

4 · Arriving at altitude (Table 9-5)

If the crew arrived from sea level less than 12 hours ago, enter the arrival time. NavCommand starts from the Table 9-5 group for the site altitude: A at 1,000–2,000 ft, B 3,000, C 4,000, D 5,000, E 6,000, F 7,000, G 8,000, H 9,000, I 10,000. It credits the time at altitude through Table 9-8, and uses the result as the minimum Dive 1 starting group.

5 · Depth gauges at altitude

Enter actual depth. A dive computer, or a gauge re-zeroed at the site, is used as read. For a sealed, sea-level-referenced gauge, add 1 fsw per 1,000 ft of elevation. A pneumofathometer takes its normal correction factor (USN Rev 7).

08

Flying or driving higher after diving (Table 9-6)

  • Uses the highest repetitive group from the last 24 hours (Note 1).
  • The column is the increase in altitude above the dive site, rounded up to the next 1,000 ft. The dive site is the elevation you entered, not the rounded-up planning altitude, because rounding the site up would understate the climb.
  • A commercial flight counts as 8,000 ft (Note 3). No interval is needed before a commercial flight from a dive site at 8,000 ft or higher (Note 4).
  • Exceptional exposure: 48 hours. A schedule with no repetitive group gets the same 48 hours, since Table 9-6 has no group for it. Above 10,000 ft: consult NAVSEA 00C (Note 2).
09

Nitrox, oxygen and CNS

  • Nitrox is planned on the air tables at the actual depth. NavCommand does not give equivalent-air-depth credit. The EAD is shown for reference only.
  • ppO₂ uses fresh- or salt-water depth (34 or 33 ft per atmosphere). At altitude it uses a surface pressure rounded slightly high, which makes ppO₂ read slightly high (conservative).
ppO₂ = (Psurface + depth ÷ 33) × FO2   ·   MOD = (ppO₂ limit ÷ FO2 − Psurface) × 33   (34 in fresh water)
  • The depth buttons stop at the MOD at ppO₂ 1.4 for the gas selected. The MOD uses the same surface pressure as the ppO₂ figure, so the two always agree.
  • CNS oxygen loading uses the NOAA single-exposure limits, interpolated between table points. It is worked out for the bottom and for each decompression stop at that stop’s ppO₂.
10

Gas planning, rock bottom and contingencies

  • Rock bottom (SCUBA): the gas for two divers to come up on one supply, under stress. Each diver breathes 2× their normal rate, never less than 1.0 cu ft/min. NavCommand allows one minute at depth to sort out the problem, then an ascent at 30 ft/min. It also adds the stop times of the plan’s Table 9-9 schedule, counting the travel between stops on top (slightly conservative). Gas use is pressure-weighted at each depth and rounded up to the next 50 psi.
  • Bailout (surface-supplied): the same calculation for one diver, checked against the bailout bottle selected.
  • The schedule used for gas planning includes the Dive 1 residual nitrogen time, so it matches the dive plan.
  • Contingency: every plan also shows the dive run 5 minutes longer, 10 fsw deeper, and both, using the same residual nitrogen, altitude correction and cold setting.
11

OSHA limits built in

RuleWhat NavCommand does
1910.424(b)(1) · SCUBA no deeper than 130 fswWarning on any plan deeper than 130 fsw: surface-supplied air only
1910.424(b)(2), 1910.425(b)(2), 1910.423(c) · chamber ready deeper than 100 fsw or outside the no-decompression limitsChamber warning on the plan; chamber, phone and transport fields on the commercial dive plan
1910.425(b)(3) · bell for in-water decompression over 120 minWarning when the schedule’s in-water stops total more than 120 min
1910.425(b)(1) · surface-supplied air no deeper than 190 fsw (220 fsw for 30 min or less)The Rev 7 air tables end at 190 fsw, so NavCommand never plans deeper
12

Worked examples

RESIDUAL NITROGEN

A diver currently in Group J (from the dive log) is planned for 60 ft / 30 min.

  1. Table 9-8: Group J at 60 fsw → RNT 58 min; ESDT = 30 + 58 = 88 min.
  2. That is past the 63-min no-decompression limit, so Table 9-9 applies: 60 fsw / 90-min schedule → total ascent time 25 min, surfacing Group O.
  3. Planned as a clean diver, the same dive would have been a no-stop dive.
COLD / STRENUOUS

60 ft / 70 min. In normal conditions this is the 70-min schedule with a 9-min ascent. Cold or strenuous, NavCommand uses the next longer schedule, 80 min, with a 16-min ascent.

ALTITUDE
  1. 6,000 ft, 100 ft dive, 90 minutes after arriving: Table 9-4 → 130 fsw; Table 9-5 → Group E, credited to D after 90 min; RNT 11 min. Any 20 fsw stop is held at 16 ft.
  2. 150 ft at a 2,000 ft site: Table 9-4 gives a sea level equivalent of 170 fsw, so NavCommand plans on the 170 fsw row. The 20 fsw stop is held at 20 × 0.930 = 18.6 → 19 ft.
SHORT SURFACE INTERVAL

60 ft / 60 min, 5 minutes on the surface, then 100 ft / 10 min. This is one dive at 100 ft for 70 min: Table 9-9 100 fsw / 70-min schedule, total ascent 138 min, flagged as exceptional exposure. The residual-nitrogen method alone would have given 50 min.

NavCommand is a planning and documentation tool based on the U.S. Navy Diving Manual, Revision 7, and 29 CFR Part 1910, Subpart T. It does not replace the employer’s safe practices manual, a qualified diving supervisor, diver training, or a calibrated depth gauge or dive computer. See also: NavCommand · Testing Results · eCFR, 29 CFR 1910 Subpart T.
Scroll to Top