INCCOMMAND · TECHNICAL METHODOLOGY
How IncCommand calculates
Every number IncCommand shows comes from the U.S. Navy Diving Manual, Revision 7 air tables, applied the way the manual applies them, with the limits of OSHA 29 CFR 1910 Subpart T on top. This page sets out each rule, where it comes from, and the few places where IncCommand is deliberately more conservative than the tables.
The tables IncCommand uses
| USN Rev 7 table | What IncCommand uses it for |
|---|---|
| Table 9-7 · No-decompression limits and repetitive group designators | No-decompression limit for each depth and the repetitive group on surfacing |
| Table 9-8 · Residual nitrogen time | Surface-interval credit (new group) and residual nitrogen time (RNT) for repetitive dives |
| Table 9-9 · Air decompression table | Stops, stop times, total ascent time and surfacing group for decompression dives |
| Table 9-4 · Sea level equivalent depth | Converting actual depth at altitude to the table row |
| Table 9-5 · Groups on initial ascent to altitude | Starting group for a team that arrived at altitude less than 12 hours ago |
| Table 9-6 · Surface interval before ascent to altitude | Wait before flying or driving higher after diving |
IncCommand plans open-circuit SCUBA on air or nitrox. It has no helium (mixed-gas) schedules; OSHA covers mixed-gas diving separately in 1910.426.
Depth and bottom time
- Depth is entered in whole feet and rounded up. The table row is the exact or next deeper published row: 10, 15, 20, 25, 30, 35, 40, 45, 50, 55, 60, then every 10 fsw to 190.
- Bottom time follows the Navy definition: from leaving the surface to leaving the bottom, rounded up to the whole minute. The schedule is the exact or next longer published bottom time.
- Maximum depth is 130 fsw, the OSHA SCUBA limit (1910.424(b)(1)). For nitrox the limit is lower: the depth where oxygen reaches 1.4 atmospheres (see section 08).
- Fresh water never makes a dive shallower in the tables. The table row always comes from the depth as entered. Water type is used only for oxygen calculations.
No-decompression limits and repetitive groups
For a no-decompression dive, IncCommand reads Table 9-7 at the table row. The repetitive group is the first group whose time is equal to or longer than the bottom time (or the equivalent single dive time on a repetitive dive). At 10–20 fsw, Table 9-7 shows no limit, and IncCommand shows “No limit.”
Cold or strenuous dives
When the Cold / Strenuous switch is on, IncCommand applies two adjustments:
- IncCommand margin (Rev 7 §9-6.1 does not require it): a decompression dive uses the next longer bottom-time schedule in Table 9-9: one row longer than the dive’s own row.
- IncCommand margin (not a Navy rule): the no-decompression limit is reduced by 20%, rounded down. This is an extra safety factor, and it is labelled as such in the app.
Decompression dives
- A dive whose bottom time (or equivalent single dive time) exceeds the adjusted no-decompression limit uses Table 9-9. IncCommand takes the exact or next longer bottom-time row for that depth.
- If that row has no stops (for example, the cold margin pushed a dive just past the limit), IncCommand uses the next row that does have stops. A dive that needs decompression always gets a schedule with stops.
- Stop depths and stop times are shown exactly as published. The total ascent time (TAT) is shown to the nearest minute; the manual prints it in minutes and seconds. The repetitive group on surfacing is the group printed on that Table 9-9 row.
- Every published Table 9-9 row to 190 fsw is loaded, including the longest rows (for example 150 fsw / 120 and 180 min) that Rev 7 lists for emergencies such as entrapment.
- Exceptional exposure (Rev 7 9-10): every row at or below the line printed in Table 9-9 where in-water air decompression becomes exceptional exposure (more than 90 minutes of decompression) is flagged, including rows that still show Group Z. The flag says what the manual says: exceptional exposure schedules are for emergencies, and planned exceptional exposure dives need Commanding Officer approval (OPNAVINST 3150.27).
- No repetitive group (9-9.1 item 9): a row that prints no repetitive group is flagged separately. No dive deeper than 20 fsw is allowed for 18 hours after it. Table 9-6 has no group for these rows, so IncCommand applies the 48-hour exceptional-exposure wait before flying or driving higher.
- Decompression mode: IncCommand plans the in-water air schedule and also shows the mode note Table 9-9 prints for that row: air/O₂ or surface decompression on oxygen (SurDO₂) strongly recommended once air stop time passes 15 minutes (9-8.4); in-water air/O₂ or SurDO₂ required below the exceptional-exposure line; SurDO₂ required, or SurDO₂ only, on the deepest bands.
- If the sea level equivalent depth is deeper than 190 fsw, or the bottom time is longer than the last Table 9-9 row for that depth, IncCommand gives no schedule and does not plan the dive: “Beyond the air tables in this app.” Rev 7 does list air schedules deeper than 190 fsw, but every air dive deeper than 190 fsw is exceptional exposure, so they are not in the planner.
Repetitive dives and residual nitrogen
Surface interval of 10 minutes or more
- The diver’s surfacing group is reduced by the surface interval using the credit table at the top of Table 9-8. The reduction always starts from the group at surfacing, never from an already-reduced group, so editing the interval cannot credit off-gassing twice.
- Once the interval passes the end of the table, the diver is clean: the next dive is not a repetitive dive.
- Otherwise IncCommand reads the residual nitrogen time (RNT) for the new group at the next dive’s table row (Table 9-8). Where Table 9-8 prints no time (“**” at 10–20 fsw, or “†” at 25 fsw for Groups O and Z, which the manual says to read from the 30 fsw row), IncCommand uses the next deeper row that has a value. A repetitive dive never leaves the diver in a lower group than they started it with.
The repetitive dive is then planned exactly like a single dive of length ESDT (equivalent single dive time), using Table 9-7 or Table 9-9.
When a repetitive dive is not allowed
- After a schedule with no repetitive group (including every exceptional exposure row, and dives beyond the tables): a red banner blocks any dive deeper than 20 fsw until 18 hours after surfacing (9-9.1 item 9). At altitude the 20 fsw test uses the sea level equivalent depth.
- A repetitive dive that would need an exceptional exposure schedule gets a red banner: Rev 7 does not allow it (9-9.1 item 10).
Surface interval under 10 minutes
The Navy treats two dives less than 10 minutes apart as one dive: the deepest depth of the two and the combined bottom time. IncCommand applies that rule. It also never lets the result come out lower than the residual-nitrogen method, so it uses whichever is longer:
A red banner tells the supervisor the dives were combined.
Where the starting group comes from
In Auto mode IncCommand works out each diver’s current group from the incident dive log: the last surfacing group, reduced for the time since surfacing. The supervisor can instead set a manual group for diving done outside the log. An altitude-arrival group (Table 9-5, section 06) is applied as a minimum, so a manual entry can never make a diver cleaner than the arrival rule allows.
Diving at altitude
IncCommand follows the USN Rev 7 altitude procedure (Chapter 9). It uses two corrections: one for the dive depth and one for the decompression stops.
1 · Which altitude column
- 300 ft or lower: no correction (sea level).
- Above 300 ft: the elevation is rounded up to the next 1,000 ft. A 6,225 ft site uses the 7,000 ft column.
- Above 10,000 ft: outside the Rev 7 procedures. IncCommand will not plan the dive.
2 · Dive depth → Table 9-4
The actual depth is looked up in Table 9-4 to get the sea level equivalent depth. That depth then goes to the next deeper row of Tables 9-7, 9-8 and 9-9. The Table 9-4 values are exactly as printed. Between 300 and 1,000 ft the manual corrects only dives deeper than 145 fsw, and its 1,000 ft column reflects that. Where Table 9-4 leaves a cell blank, the depth converts to deeper than 190 fsw and the dive is not planned.
3 · Decompression stops → actual stop depth
Table 9-9 stop depths are sea-level depths. At altitude each stop is held shallower, in proportion to the lower surface pressure. Stop times do not change.
The ratios are the manual’s own, to three decimals (below). With them the formula gives exactly the Equivalent Stop Depths printed under Table 9-4 for 10–60 fsw stops, and the same formula covers deeper stops (Rev 7 9-13.1.2). Between 300 and 1,000 ft, a dive to 145 fsw or shallower is not corrected at all, so its stops are the table stops; dives deeper than that use the 1,000 ft ratio.
IncCommand shows the actual stop depth with the table stop underneath. The report and the CSV export carry both.
| Altitude (ft) | 1,000 | 2,000 | 3,000 | 4,000 | 5,000 | 6,000 | 7,000 | 8,000 | 9,000 | 10,000 |
|---|---|---|---|---|---|---|---|---|---|---|
| Palt ÷ Psea | 0.964 | 0.930 | 0.896 | 0.864 | 0.832 | 0.801 | 0.772 | 0.743 | 0.715 | 0.688 |
| 20 fsw stop held at | 19 ft | 19 ft | 18 ft | 17 ft | 17 ft | 16 ft | 15 ft | 15 ft | 14 ft | 14 ft |
| 30 fsw stop held at | 29 ft | 28 ft | 27 ft | 26 ft | 25 ft | 24 ft | 23 ft | 22 ft | 21 ft | 21 ft |
4 · Arriving at altitude (Table 9-5)
A diver who has just come up from sea level still carries extra nitrogen. If the team arrived less than 12 hours ago, enter the arrival time. IncCommand then:
- Starts each diver at the Table 9-5 group for the site altitude: A at 1,000–2,000 ft, B 3,000, C 4,000, D 5,000, E 6,000, F 7,000, G 8,000, H 9,000, I 10,000.
- Credits the time spent at altitude as a surface interval (Table 9-8).
- Uses the result as every diver’s minimum starting group. After 12 hours the arrival group no longer applies.
The table assumes the team came up from sea level, so it is conservative for a team coming from a lower elevation.
5 · Depth gauges at altitude
Enter actual depth. A dive computer, or a gauge re-zeroed at the site, is used as read. A sealed, sea-level-referenced mechanical gauge reads low at altitude: add 1 fsw for every 1,000 ft of elevation before entering it (USN Rev 7).
Flying or driving higher after diving (Table 9-6)
- IncCommand uses each diver’s highest repetitive group from the last 24 hours (Note 1).
- The column is the increase in altitude above the dive site, rounded up to the next 1,000 ft. The dive site is the elevation you entered, not the rounded-up planning altitude, because rounding the site up would understate the climb. If you picked a table altitude without entering an elevation, IncCommand uses the low edge of that band.
- A commercial flight is treated as an ascent to 8,000 ft (cabin pressure, Note 3). If the dive site is at 8,000 ft or higher, no interval is needed before a commercial flight (Note 4).
- Exceptional exposure: wait 48 hours. A schedule with no repetitive group gets the same 48 hours, since Table 9-6 has no group for it. Above 10,000 ft, Table 9-6 does not apply (Note 2): consult NAVSEA 00C.
The countdown starts from each diver’s logged surfacing time.
Nitrox, oxygen and CNS
- Nitrox is planned on the air tables at the actual depth. IncCommand does not give equivalent-air-depth credit. The EAD is shown for reference only. This is more conservative than planning at the EAD.
- Oxygen partial pressure uses fresh- or salt-water depth (34 or 33 ft per atmosphere). At altitude, IncCommand uses a surface pressure rounded slightly high, which makes ppO₂ read slightly high (conservative).
- Depth limit for nitrox: the deepest depth at which ppO₂ stays at or below 1.4, worked out from sea-level surface pressure (conservative at altitude). Depths beyond it are not offered. EAN32 stops at 110 ft and EAN36 at 90 ft on the depth buttons; the OSHA 130 fsw cap applies to every gas.
- CNS oxygen loading uses the NOAA single-exposure limits, interpolated between table points. Each dive adds bottom time ÷ the limit at its ppO₂. The total across the day warns at 60% and alerts at 80%.
Live timing on scene
- Start records the time the diver leaves the surface. Left bottom stops the bottom-time clock. Actual bottom time is rounded up to the whole minute.
- If nobody taps Left bottom, a no-decompression dive counts all the way to surfacing (conservative). For a planned decompression dive, IncCommand subtracts the planned total ascent time and marks the bottom time as estimated.
- If the actual bottom time is longer than planned, IncCommand re-runs the dive from the actual time. It keeps whichever surfacing group is later. If the longer time needed decompression that was not planned, or a longer schedule than the one planned, the dive is flagged as omitted decompression, with instructions to monitor for DCS and contact the diving medical officer / chamber.
- Bottom-time alerts sound at 5 minutes left, 1 minute left, time up, and when the no-decompression limit is exceeded.
Contingency schedules and rock bottom
Contingency: every plan also shows the same lookup for the dive run 5 minutes longer, 10 fsw deeper, and both. Each uses the same residual nitrogen, altitude correction and cold setting as the plan.
Rock bottom is the gas to bring two divers up on one cylinder, under stress:
- Each diver breathes 2× their normal rate, never less than 1.0 cu ft/min. The SAC rate is entered in psi/min on an aluminum 80.
- One minute at depth to sort out the problem.
- Ascent at 30 ft/min through any Table 9-9 stops in the plan.
Gas use is pressure-weighted at each depth, and the result is rounded up to the next 50 psi. Pony bottles and reserves are extra.
OSHA limits built in
| Rule | What IncCommand does |
|---|---|
| 1910.424(b)(1) · SCUBA no deeper than 130 fsw | Depth entry and depth buttons stop at 130 fsw |
| 1910.424(b)(2) · chamber ready deeper than 100 fsw or outside the no-decompression limits | Chamber warning on the plan; “Chamber confirmed” line on the report |
| 1910.424(b)(3) · line-tended in current over 1 knot | Warning when the current entered is over 1 kt (caution from 0.8 kt) |
| 1910.424(c)(1) · standby diver while a diver is in the water | Staffing alert by operation mode |
| 1910.421(b), 1910.423(b) and (d), 1910.440 | Emergency-aid contacts, post-dive check and DCS record, dive record fields, and a retention reminder on the report |
Worked examples
The team flies by helicopter to a 6,000 ft lake and the diver goes to 100 ft 90 minutes later. (This is the worked example from the manual.)
- Table 9-4: 100 ft at 6,000 ft → sea level equivalent 130 fsw.
- Table 9-5: arrival at 6,000 ft → Group E; 90 minutes at altitude → Group D.
- Table 9-8: Group D at 130 fsw → RNT 11 min, added to the bottom time.
At a 6,000 ft site, Table 9-9 calls for a 20 fsw stop. 20 × 0.801 = 16.0, so the diver holds the stop at 16 ft for the full published time.
A diver does 60 ft for 60 min, surfaces for 5 minutes, then goes to 100 ft for 10 min.
- Under 10 minutes apart, so this is one dive: deepest depth 100 ft and combined bottom time 70 min.
- Table 9-9: 100 fsw / 70-min schedule → total ascent time 138 min. That row is below the exceptional-exposure line, so IncCommand flags it.