Navy Dive Tables 101: A Beginner’s Guide to Mastering US Navy Rev 7

The U.S. Navy dive tables are not one table or one algorithm. They are a set of procedures for specific diving operations. To use them correctly, first identify the table that answers your question, then follow the manual’s definitions and procedures, not just a number pulled from a chart.

This guide introduces the air tables in the U.S. Navy Diving Manual, Revision 7, Change A. It is an orientation, not a dive plan or a replacement for the complete manual, dive training, or your organization’s procedures.

Start with the right manual and chapter

Revision 7, Change A is the version addressed here: Revision 7 was issued in December 2016, with Change A dated April 2018. Its air-decompression tables are in Volume 2, Chapter 9, “Air Decompression.”

For source material, use the U.S. Navy Diving Manual listing from NAVSEA and confirm you are consulting the correct revision and change. Do not assume that a table excerpt, older manual, or online calculator includes every note and procedure in the published source.

One important distinction: USN Rev 7 air tables are not the same planning method as a recreational or technical Bühlmann ZHL-16C planner. They use different methods and procedures. Do not combine their outputs as if they were interchangeable.

Three tables to know first

Diagram introducing Chapter 9 Tables 9-7, 9-8, and 9-9

For a first pass through Chapter 9, learn what each of these tables is for:

Table Purpose
9-7 No-decompression limits and repetitive group designations for no-decompression air dives
9-8 Residual nitrogen time for repetitive air dives
9-9 Air decompression schedules, including in-water air/O₂ and surface decompression on oxygen (SurDO₂) options

The practical sequence depends on the dive. Table 9-7 helps determine whether a no-decompression dive remains within its listed limit and provides a repetitive group. For a repetitive dive, Table 9-8 is used to account for residual nitrogen. If a decompression schedule is required, Table 9-9 provides the relevant schedule and procedures.

That overview is not enough to plan a dive. The manual’s instructions, table notes, dive conditions, and operational requirements matter.

What a no-decompression limit tells you

A no-decompression limit (NDL) is the table’s maximum bottom time for a no-decompression air dive at a listed depth. In Table 9-7, for example:

Depth No-decompression limit
60 fsw 63 min
100 fsw 25 min
130 fsw 12 min
190 fsw 5 min

These figures are useful for understanding the table’s structure. They are not recommendations for how long to stay at a depth, and they do not account for every factor that affects a real dive. Actual depth and time, the ascent profile, repetitive-dive history, altitude, and applicable procedures can all matter.

Also, “no-decompression” does not mean “no ascent procedure.” Divers must still follow the applicable ascent and operational procedures. A listed limit should never be used on its own to decide that a dive is appropriate.

The manual’s use of fsw means feet of seawater, or equivalent static pressure head. A table value is meaningful only when read with the correct depth, time, and other required details.

Repetitive dives: why the group letter matters

Visual overview of no-decompression limits, residual nitrogen, and decompression schedules

After a dive, Table 9-7 assigns a repetitive group designation. That letter represents a diver’s residual nitrogen status under the table’s procedure. Table 9-8 uses the group and surface interval to determine residual nitrogen time for a subsequent air dive.

In plain language: a repetitive dive does not begin as though the previous dive never happened. The table procedure accounts for nitrogen remaining in the diver’s body. Read the relevant group and surface-interval entries carefully; do not estimate an adjusted limit from memory or carry over a group using an informal shortcut.

This is also why a quick NDL lookup is not enough for planning a series of dives. The dive history and interval between dives matter. The next article in this series will work through Table 9-8, residual nitrogen time, and surface intervals in more detail.

When Table 9-9 applies

Table 9-9 is the air decompression table. It brings together schedules and procedures for in-water air decompression, in-water air/O₂, and SurDO₂. The applicable option depends on the table entry and the manual’s directions; these modes should not be treated as interchangeable choices.

The table specifies a 75 feet per minute (fpm) descent rate and a 30 fpm ascent rate. For all in-water decompressions, the last water stop is at 20 fsw. The manual also states that divers are eligible for surface decompression after completing the 40 fsw water stop. At 20 fsw and shallower, the table has no bottom-time limit. That statement is specific to the table’s application; it does not mean a dive at shallow depth has no practical, physiological, or operational limits.

Ascent profile graphic showing Rev 7 rates and safety notes: SurDO2 eligible at 40 FSW after completing any deeper required water stops

These details are easy to misread when a table is reduced to a small graphic. A stop depth, stop time, ascent rate, and decompression mode are parts of a procedure. Do not extract one element and apply it outside the complete schedule and instructions.

A practical way to study the tables

Use this sequence when learning the chapter:

  1. Confirm the source. Check that you have Revision 7, Change A, and the correct volume and chapter.
  2. Identify the dive context. Determine which mode and table apply; this article covers the air tables, not every Navy diving procedure.
  3. Find the applicable table entry. Match the required depth and bottom-time information, following the manual’s instructions for selecting entries.
  4. Check repetitive status. If the dive is repetitive, use the prescribed group, surface interval, and residual nitrogen procedure.
  5. Read the entire schedule and its notes. Do not rely on a single number or a cropped table excerpt.
  6. Use the controlling procedures. A qualified supervisor, applicable safe practices manual, and current operational requirements remain essential.

For commercial diving, OSHA’s Commercial Diving Operations standard, 29 CFR Part 1910, Subpart T includes requirements related to decompression tables, dive profiles, and records. Which requirements apply depends on the operation and context. Public safety and recreational diving have their own governing procedures; the Navy manual should not be assumed to replace them.

Where software fits, and where it does not

Software can help apply a defined table procedure consistently, but it cannot supply judgment, training, supervision, or missing operational information. DepthPlanner’s NavCommand is designed for commercial planning using USN Rev 7 tables. Its calculation methodology describes how it handles table entries and related procedures.

For recreational and technical planning, DiveCommand uses the Bühlmann ZHL-16C model. That is a different approach from the Navy air tables. Choose the planning method appropriate to the dive and your established procedures; do not mix methods simply because both provide dive-planning outputs.

A planned companion resource will cover Table 9-7 in greater detail and provide a printable one-page reference graphic. Any quick-reference graphic should be checked against the complete manual and treated as an aid, not as a substitute for the source.

Keep the source in view

The key to learning Navy dive tables is understanding what each table does and following its full procedure. Table 9-7 covers no-decompression limits and repetitive groups; Table 9-8 addresses residual nitrogen time; Table 9-9 provides air decompression schedules and associated options.

Use the official NAVSEA publications page to locate the manual, and consult the complete current source and applicable operational guidance before using any table. This article is educational, not a dive plan. It does not replace diver training, a qualified dive supervisor, or established safety procedures.

Scroll to Top